Guided Wave Radar
Level Transmitter
Enhanced Model 705
Software v3.x
Installation and Operating Manual
Vista de página 0
1 2 3 4 5 6 ... 67 68

Resumo do Conteúdo

Página 1 - Level Transmitter

Guided Wave RadarLevel TransmitterEnhanced Model 705Software v3.xInstallation and Operating Manual

Página 2 - WARNINGS

10WARNING! The Model 7xD, 7xR or 7xT overfill probes should beused for Safety Shutdown/Overfill applications. All otherGuided Wave Radar probes should

Página 3

2.4.2 Installing a Twin Rod Probe(Models 7xB, 7x5, and 7x7)Before installing, make sure the:• Model and serial numbers on the nameplates of theECLIPSE

Página 4 - 1.0 QuickStart Installation

1257-600 Eclipse®Guided Wave Radar Transmitter2.4.2.2 To install a Model 7x7 standard flexible twin rod probe: Make sure the process connection is at

Página 5 - 1.2.1 Probe

1357-600 Eclipse®Guided Wave Radar Transmitter2. Ratio of Diameter: Length (A:B) is 1:1 or greater; anyratio <1:1 (e.g., a 2"× 6" nozzle

Página 6 - 1.2.2 Transmitter

14 Align the probe process connection with the threaded orflanged mounting on the vessel. For threaded connections, tighten the hex nut of the probe

Página 7 - Probe Length

 Make sure that there is at least 1" (25 mm) spacingbetween the active probe rod and any part of the tank(walls, stillwell, pipes, support beams

Página 8 - 2.0 Complete Installation

1657-600 Eclipse®Guided Wave Radar Transmitter2.4.5 Installing the TransmitterThe transmitter can be ordered for installation as anIntegral or Remote

Página 9 - 2.3.2 Equipment and Tools

1757-600 Eclipse®Guided Wave Radar TransmitterRed (+)Black (-)(+)(-)2.5 WiringCaution: All HART versions of the ECLIPSE Model 705 transmitteroperate a

Página 10 - Guided Wave Radar Transmitter

1857-600 Eclipse®Guided Wave Radar Transmitter2.5.2 Intrinsically SafeAn intrinsically safe (IS) installation potentially has flam-mable media present

Página 11 - (Models 7xB, 7x5, and 7x7)

1957-600 Eclipse®Guided Wave Radar Transmitter2.6 Configuring the TransmitterThe ECLIPSE transmitter comes configured from the factorybut can be recon

Página 12 - (Models 7x1, 7x2, 7xF, 7xJ)

57-600 Eclipse®Guided Wave Radar TransmitterRead this Manual Before InstallingThis manual provides information on the Eclipse®trans-mitter. It is impo

Página 13

2057-600 Eclipse®Guided Wave Radar Transmitter2.6.3 Transmitter Display and KeypadThe ECLIPSE transmitter has an optional liquid crystal display(LCD)

Página 14 - 0.50" (13 mm) Ø

2157-600 Eclipse®Guided Wave Radar Transmitter2.6.5 Model 705 Menu: Step-By-Step ProcedureThe following tables provide a complete explanation ofthe so

Página 15 - Bulk Solids Probe

2257-600 Eclipse®Guided Wave Radar Transmitter2.6.5.1 Measurement Type: Level Only (Loop Control = Level)Display Action Comment12SenstvtyxxxEnter valu

Página 16 - 2.4.5.2 Remote Mount

2357-600 Eclipse®Guided Wave Radar Transmitter2.6.5.1 Measurement Type: Level Only (Loop Control = Level)Display Action Comment33DispFact(select)Selec

Página 17 - Wiring Diagram

2457-600 Eclipse®Guided Wave Radar Transmitter2.6.5.2 Measurement Type: Level and Volume (Loop Control = Volume)Display Action Comment1*Status**Volume

Página 18 - 2.5.3 Explosion Proof

2557-600 Eclipse®Guided Wave Radar Transmitter2.6.5.2 Measurement Type: Level and Volume (Loop Control = Volume)Display Action Comment22SZ Fault(selec

Página 19 - 2.6.1 Operating Parameters

2657-600 Eclipse®Guided Wave Radar Transmitter2.6.5.2 Measurement Type: Level and Volume (Loop Control = Volume)Display Action Comment44Fid GainxxxSup

Página 20

2757-600 Eclipse®Guided Wave Radar Transmitter2.6.5.3 Measurement Type: Interface Level (Loop Control = Interface Level)Display Action Comment1*Status

Página 21

2857-600 Eclipse®Guided Wave Radar Transmitter2.6.5.3 Measurement Type: Interface Level (Loop Control = Interface Level)Display Action Comment21SZ Fau

Página 22

2957-600 Eclipse®Guided Wave Radar Transmitter2.6.5.3 Measurement Type: Interface Level (Loop Control = Interface Level)Display Action Comment43FidTic

Página 23

Table of Contents1.0 QuickStart Installation1.1 Getting Started...41.1.1 Equipment and Tools ..

Página 24

3057-600 Eclipse®Guided Wave Radar Transmitter2.6.5.4 Measurement Type: Interface and VolumeDisplay Action Comment1*Status**IfcLvl**% Out ** Loop *Tra

Página 25

3157-600 Eclipse®Guided Wave Radar Transmitter2.6.5.4 Measurement Type: Interface and VolumeDisplay Action Comment24BlockDisxx.x luEnter distance belo

Página 26

3257-600 Eclipse®Guided Wave Radar Transmitter2.6.5.4 Measurement Type: Interface and VolumeDisplay Action Comment46Hist RstPress Enter and select yes

Página 27

3357-600 Eclipse®Guided Wave Radar Transmitter2.6.6 Offset DescriptionThe parameter referred to as Lvl Ofst in the ECLIPSE menuis the desired level re

Página 28

342.6.7 Strapping Table DescriptionThe Model 705 is available with a 20-point custom strap-ping table. Up to 20 pairs of Level—Volume points can beent

Página 29

3557-600 Eclipse®Guided Wave Radar Transmitter2.7 Configuration Using HARTA HART (Highway Addressable Remote Transducer)remote unit, such as a HART co

Página 30

3657-600 Eclipse®Guided Wave Radar Transmitter1 Calibration 2 Basic Setup 3 Advanced Setup 4 Diagnostics5 Review1 Device Setup 2 Level 3 % Range

Página 31

3757-600 Eclipse®Guided Wave Radar Transmitter2.8 FOUNDATION fieldbus™Digital Communications2.8.1 DescriptionFOUNDATION fieldbus is a digital communic

Página 32

3857-600 Eclipse®Guided Wave Radar TransmitterDetails regarding cable specifications, grounding, termination,and other network information can be foun

Página 33 - 2.6.6 Offset Description

3957-600 Eclipse®Guided Wave Radar Transmitter2.8.3 Device ConfigurationDevice DescriptionsThe function of a Fieldbus device is determined by thearran

Página 34

1.0 QuickStart InstallationThe QuickStart Installation procedures provide the keysteps for mounting, wiring, and configuring the Eclipse®level transmi

Página 35 - 2.7.2 Display Menu

4057-600 Eclipse®Guided Wave Radar TransmitterFISCO certifying agencies have limited the maximumsegment length to 1000 meters because the FISCO modeld

Página 36

4157-600 Eclipse®Guided Wave Radar Transmitter3.2.2 Interface DetectionThe ECLIPSE Model 705, when used with the Model 7xTcoaxial probe, is a transmit

Página 37 - Model 705 3.x

4257-600 Eclipse®Guided Wave Radar Transmitter3.2.3 Time Domain Reflectometry (TDR)TDR uses pulses of electromagnetic (EM) energy to mea-sure distance

Página 38 - 2.8.2 Benefits

4357-600 Eclipse®Guided Wave Radar TransmitterLEVEL, % OUTPUT and LOOP values Basic configuration data is Reconfigure the Probe Model and/or Probeare

Página 39 - 2.8.4 Intrinsically Safe

4457-600 Eclipse®Guided Wave Radar Transmitter3.3.2 Status MessagesDisplay Message Action CommentOK None Normal operating modeInitial None Program is

Página 40 - 3.0 Reference Information

4557-600 Eclipse®Guided Wave Radar Transmitter3.3.2 Status MessagesDisplay Message Action CommentLo Temp Present temperature inelectronics compartment

Página 41 - 3.2.2 Interface Detection

463.3.3 Troubleshooting ApplicationsThere are numerous causes for application problems.Media buildup on the probe and stratification are coveredhere.

Página 42

473.3.3.3 Model 705 (Single Rod Application)• NozzlesNozzles can create false echoes that can cause diagnosticmessages and/or errors in measurement. I

Página 43

FM 705-5XXX-1XX Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D705-5XXX-2XX Class II, Div. 1; Groups E, F, & G T4Class III, Type 4X, I

Página 44 - 3.3.2 Status Messages

4957-600 Eclipse®Guided Wave Radar Transmitter3.4.2 Agency Specifications – Intrinsically Safe Installation

Página 45

1.1.2 Configuration InformationSome key information is needed to configure theECLIPSE transmitter. Complete the following operatingparameters table be

Página 46

5057-600 Eclipse®Guided Wave Radar Transmitter3.4.3 Agency Specifications – FOUNDATION fieldbus System

Página 47

513.5 Parts3.5.1 Replacement PartsItem Description Part Number Electronic moduleHART with display (SIL 1) Z31-2835-001HART without display (SIL 1) Z3

Página 48 - 3.4 Agency Approvals

5257-600 Eclipse®Guided Wave Radar Transmitter3.6 Specifications3.6.1 FunctionalSystem DesignMeasurement Principle Guided time-of-flight via time doma

Página 49

53Reference Conditions  Reflection from water at +70° F (+20° C) with 72" coaxial probe(CFD threshold)Linearity  Coaxial/Twin Rod Probes: <0

Página 50 - OUNDATION fieldbus System

5457-600 Eclipse®Guided Wave Radar TransmitterReference Conditions Reflection from liquid of selected dielectric at +70° F (+20° C) with 72" prob

Página 51 - 3.5 Parts

Dual-element Probes5557-600 Eclipse®Guided Wave Radar TransmitterSingle Rod ProbesDistance to Probe Acceptable Objects<6" Continuous, smooth,

Página 52 - 3.6 Specifications

5657-600 Eclipse®Guided Wave Radar TransmitterTemperature/Pressure Charts3.6.6 Physicalinches (mm)33.00 or 144(838 or 3650)3.75(95)3.00(76)2.37(60)2.0

Página 53 - 3.6.2 Performance - Model 705

5757-600 Eclipse®Guided Wave Radar Transmitter3.6.6 Physical – Coaxial Probesinches (mm)Eclipse®with 7XS ProbeFlanged ConnectionEclipse®with 7XS Probe

Página 54 - 3.6.4 Process Conditions

5857-600 Eclipse®Guided Wave Radar Transmitter3.6.6 Physical – Twin Rod Probesinches (mm)Eclipse®with 7x7 Twin Rod Flexible ProbeFlanged or NPT Connec

Página 55 - 3.6.5 Probe Specifications

5957-600 Eclipse®Guided Wave Radar Transmitter3.6.6 Physical – Single Rod Probesinches (mm)Eclipse®with 7xF-E ProbeHygienic ConnectionProbeInsertion

Página 56 - 3.6.6 Physical

61.2.2 Transmitter Tighten the hex nut of the probe process connection orflange bolts.NOTE: Leave the plastic protective cap in place until ready toi

Página 57

3.7 Model Numbers3.7.1 Transmitter6057-600 Eclipse®Guided Wave Radar Transmitter03⁄4" NPT1 M201 Cast aluminum, dual compartment, 45° angle2 316 s

Página 58

D Coaxial High Temp./High Pressure3⁄4" processconnectionor largerDielectric range ≥1.4R Coaxial Overfill ProbeL Coaxial High Temp./High Pressure

Página 59

3.7.2 Probe6257-600 Eclipse®Guided Wave Radar Transmitter75L 3" 900# ANSI Ring Joint Flange 5M 3" 1500# ANSI Ring Joint Flange 5N 3"

Página 60 - 4" NPT

6357-600 Eclipse®Guided Wave Radar Transmitter7TT 31⁄2" 600# Fisher®- Proprietary Carbon Steel (249B) Torque Tube FlangeTU 31⁄2" 600# Fisher

Página 61 - 3.7.2 Probe

Accuracy The maximum positive and negative % deviation over thetotal span.ANSI American National Standards Institute.ATEX ATmospheric EXplosive Europe

Página 62

Radar Radio Detection And Ranging Uses EM energy and highspeed timing circuits to determine distance. Original Radar devicesused energy in the radio f

Página 63 - DIN FLANGE CONNECTIONS

Copy blank page and store calibration data for future reference and troubleshooting.Item Value Value ValueVessel NameVessel #Process MediumTag #Electr

Página 64 - Glossary

6757-600 Eclipse®Guided Wave Radar TransmitterCopy blank page and store calibration data for future reference and troubleshooting.Item Value Value Val

Página 65

BULLETIN: 57-600.20EFFECTIVE: October 2012SUPERSEDES: March 20125300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-94

Página 66 - 705 Eclipse

1.4 QuickStart ConfigurationThe ECLIPSE transmitter comes configured with defaultvalues from the factory but can be reconfigured in the shop(disregard

Página 67

857-600 Eclipse®Guided Wave Radar Transmitter2.0 Complete InstallationThis section provides detailed procedures for properlyinstalling and configuring

Página 68 - SUPERSEDES: March 2012

92.3 Before You Begin2.3.1 Site PreparationEach ECLIPSE transmitter is built to match the specificphysical specifications of the required installation